Sign Up
Log In
Log In
or
Sign Up
Places
All Projects
Status Monitor
Collapse sidebar
SUSE:SLE-15-SP1:GA
patchinfo.15498
_patchinfo
Overview
Repositories
Revisions
Requests
Users
Attributes
Meta
File _patchinfo of Package patchinfo.15498
<patchinfo incident="15498"> <issue tracker="bnc" id="1168067">sapconf: Setting illegal values for vm.dirty_bytes/vm.dirty_background_bytes</issue> <issue tracker="bnc" id="1150870">sapconf postinstall script contains an invalid sed command</issue> <issue tracker="bnc" id="1166925">Logrotate feature missing in sapconf</issue> <issue tracker="bnc" id="1139176">sapconf does not complain about an improper tuned profile</issue> <issue tracker="bnc" id="1150868">sapconf postinstall script contains an invalid sed command</issue> <issue tracker="bnc" id="1168840">sapconf: Switch to /etc/security/limits.d</issue> <issue tracker="bnc" id="1124453">sapconf: absolute path for tuned script.sh</issue> <issue tracker="jsc" id="SLE-10989"/> <issue tracker="jsc" id="SLE-10986"/> <issue tracker="jsc" id="SLE-11141"/> <issue tracker="jsc" id="SLE-11144"/> <packager>AngelaBriel</packager> <rating>moderate</rating> <category>recommended</category> <summary>Recommended update for sapconf</summary> <description>This update for sapconf fixes the following issues: - Check the values of the 'vm.dirty_*' settings to be in a valid range before activating or restoring these system values. (bsc#1168067) - Add a logrotate drop-in file for sapconf to control the size of the logfile. (bsc#1166925) - Implement and use the system wide security limits. (bsc#1168840) - Add support multi-queued scheduler for block devices. (jsc#SLE-11141, jsc#SLE-11144) - Remove usage of tuned from sapconf (jsc#SLE-10986, jsc#SLE-10989): - Only ONE configuration file for sapconf - All parameters of the tuned profile defined in tuned.conf sapconf - Implement Switching a sapconf profile. - Prevent sapconf related tuned error messages by turning off tuned in the preinstall phase and removing the 'active' sapconf profile. - If sapconf detects an improper tuned profile during start notes that the log, fails the start deliberatly and guides the administrator to the problem. (bsc#1139176) - Use absolute path in the configuration file. (bsc#1124453) - Replace the delimiter for a sed command in postinstall script, because of conflicts with rpm macros. (bsc#1150868, bsc#1150870) </description> </patchinfo>
Locations
Projects
Search
Status Monitor
Help
OpenBuildService.org
Documentation
API Documentation
Code of Conduct
Contact
Support
@OBShq
Terms
openSUSE Build Service is sponsored by
The Open Build Service is an
openSUSE project
.
Sign Up
Log In
Places
Places
All Projects
Status Monitor