File 0211-pc-bios-s390-ccw-don-t-try-to-read-.patch of Package qemu-testsuite
From: Marc Hartmayer <mhartmay@linux.ibm.com> Date: Fri, 16 Apr 2021 09:47:36 +0200 Subject: pc-bios/s390-ccw: don't try to read the next block if end of chunk is reached Git-commit: a6625d38cce3901a7c1cba069f0abcf743a293f1 References: bsc#1186290 Don't read the block if a null block number is reached, because this means that the end of chunk is reached. Reviewed-by: Collin Walling <walling@linux.ibm.com> Signed-off-by: Marc Hartmayer <mhartmay@linux.ibm.com> Message-Id: <20210416074736.17409-1-mhartmay@linux.ibm.com> Signed-off-by: Thomas Huth <thuth@redhat.com> Signed-off-by: Cho, Yu-Chen <acho@suse.com> --- pc-bios/s390-ccw/bootmap.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/pc-bios/s390-ccw/bootmap.c b/pc-bios/s390-ccw/bootmap.c index fd72714de4997947dc0063f8c183..babe7ac9381518eec730c20f1d03 100644 --- a/pc-bios/s390-ccw/bootmap.c +++ b/pc-bios/s390-ccw/bootmap.c @@ -212,7 +212,7 @@ static int eckd_get_boot_menu_index(block_number_t s1b_block_nr) next_block_nr = eckd_block_num(&s1b->seek[i + 1].chs); } - if (next_block_nr) { + if (next_block_nr && !is_null_block_number(next_block_nr)) { read_block(next_block_nr, s2_next_blk, "Cannot read stage2 boot loader"); }
Locations
Projects
Search
Status Monitor
Help
OpenBuildService.org
Documentation
API Documentation
Code of Conduct
Contact
Support
@OBShq
Terms
openSUSE Build Service is sponsored by
The Open Build Service is an
openSUSE project
.
Sign Up
Log In
Places
Places
All Projects
Status Monitor