Sign Up
Log In
Log In
or
Sign Up
Places
All Projects
Status Monitor
Collapse sidebar
SUSE:SLE-15-SP7:Update
pacemaker.20188
bsc#1174696-0003-Doc-controller-Pacemaker-Expla...
Overview
Repositories
Revisions
Requests
Users
Attributes
Meta
File bsc#1174696-0003-Doc-controller-Pacemaker-Explained-improve-the-docum.patch of Package pacemaker.20188
From 2c54a4c9f9bc71cd454d02ea50c65569d064fcb0 Mon Sep 17 00:00:00 2001 From: "Gao,Yan" <ygao@suse.com> Date: Fri, 14 Aug 2020 13:31:43 +0200 Subject: [PATCH 3/3] Doc: controller, Pacemaker Explained: improve the documentation of `stonith-watchdog-timeout` cluster option This commit also marks out the default value `0` of `stonith-watchdog-timeout` cluster option in the metadata of controller to be consistent with "Pacemaker Explained". --- daemons/controld/controld_control.c | 22 +++++++++++++++++--- doc/Pacemaker_Explained/en-US/Ch-Options.txt | 20 +++++++++++++++--- doc/sphinx/Pacemaker_Explained/options.rst | 22 ++++++++++++++++---- 3 files changed, 54 insertions(+), 10 deletions(-) Index: pacemaker-2.0.4+20200616.2deceaa3a/daemons/controld/controld_control.c =================================================================== --- pacemaker-2.0.4+20200616.2deceaa3a.orig/daemons/controld/controld_control.c +++ pacemaker-2.0.4+20200616.2deceaa3a/daemons/controld/controld_control.c @@ -612,10 +612,26 @@ static pcmk__cluster_option_t crmd_opts[ }, { "stonith-watchdog-timeout", NULL, "time", NULL, - NULL, pcmk__valid_sbd_timeout, + "0", pcmk__valid_sbd_timeout, "How long to wait before we can assume nodes are safely down " - "when sbd is in use", - NULL + "when watchdog-based self-fencing via SBD is in use", + "If nonzero, along with `have-watchdog=true` automatically set by the " + "cluster, when fencing is required, watchdog-based self-fencing " + "will be performed via SBD without requiring a fencing resource " + "explicitly configured. " + "If `stonith-watchdog-timeout` is set to a positive value, unseen " + "nodes are assumed to self-fence within this much time. +WARNING:+ " + "It must be ensured that this value is larger than the " + "`SBD_WATCHDOG_TIMEOUT` environment variable on all nodes. " + "Pacemaker verifies the settings individually on all nodes and " + "prevents startup or shuts down if configured wrongly on the fly. " + "It's strongly recommended that `SBD_WATCHDOG_TIMEOUT` is set to " + "the same value on all nodes. " + "If `stonith-watchdog-timeout` is set to a negative value, and " + "`SBD_WATCHDOG_TIMEOUT` is set, twice that value will be used. " + "+WARNING:+ In this case, it's essential (currently not verified by " + "pacemaker) that `SBD_WATCHDOG_TIMEOUT` is set to the same value on " + "all nodes." }, { "stonith-max-attempts", NULL, "integer", NULL, Index: pacemaker-2.0.4+20200616.2deceaa3a/doc/Pacemaker_Explained/en-US/Ch-Options.txt =================================================================== --- pacemaker-2.0.4+20200616.2deceaa3a.orig/doc/Pacemaker_Explained/en-US/Ch-Options.txt +++ pacemaker-2.0.4+20200616.2deceaa3a/doc/Pacemaker_Explained/en-US/Ch-Options.txt @@ -272,9 +272,23 @@ immediately re-attempt it. | stonith-watchdog-timeout | 0 | indexterm:[stonith-watchdog-timeout,Cluster Option] indexterm:[Cluster,Option,stonith-watchdog-timeout] -If nonzero, rely on hardware watchdog self-fencing. If positive, assume unseen -nodes self-fence within this much time. If negative, and the -SBD_WATCHDOG_TIMEOUT environment variable is set, use twice that value. +If nonzero, along with `have-watchdog=true` automatically set by the +cluster, when fencing is required, watchdog-based self-fencing +will be performed via SBD without requiring a fencing resource +explicitly configured. +If `stonith-watchdog-timeout` is set to a positive value, unseen +nodes are assumed to self-fence within this much time. +WARNING:+ +It must be ensured that this value is larger than the +`SBD_WATCHDOG_TIMEOUT` environment variable on all nodes. +Pacemaker verifies the settings individually on all nodes and +prevents startup or shuts down if configured wrongly on the fly. +It's strongly recommended that `SBD_WATCHDOG_TIMEOUT` is set to +the same value on all nodes. +If `stonith-watchdog-timeout` is set to a negative value, and +`SBD_WATCHDOG_TIMEOUT` is set, twice that value will be used. ++WARNING:+ In this case, it's essential (currently not verified by +pacemaker) that `SBD_WATCHDOG_TIMEOUT` is set to the same value on +all nodes. | concurrent-fencing | FALSE | indexterm:[concurrent-fencing,Cluster Option]
Locations
Projects
Search
Status Monitor
Help
OpenBuildService.org
Documentation
API Documentation
Code of Conduct
Contact
Support
@OBShq
Terms
openSUSE Build Service is sponsored by
The Open Build Service is an
openSUSE project
.
Sign Up
Log In
Places
Places
All Projects
Status Monitor