Sign Up
Log In
Log In
or
Sign Up
Places
All Projects
Status Monitor
Collapse sidebar
Please login to access the resource
openSUSE:Leap:15.0:Rings:1-MinimalX
s390-tools
s390-tools-sles15-lsluns-enhance-usage-statemen...
Overview
Repositories
Revisions
Requests
Users
Attributes
Meta
File s390-tools-sles15-lsluns-enhance-usage-statement-and-man-page.patch of Package s390-tools
Subject: [PATCH] [BZ 161888] lsluns: enhance usage statement and man page From: Jens Remus <jremus@linux.vnet.ibm.com> Description: lsluns: Fix filter handling and documentation enhancements. Symptom: lsluns lists all LUNs discovered in the FC SAN despite user given filter(s) that do not match anything: # lsluns -c 0.0.5080 No valid combination found for adapter '0.0.5080'. Removing from resource list. No valid parameters left, using all available resources in system. Scanning for LUNs on adapter 0.0.5090 ... lsluns prints the message "No valid combination found for {adapter|port} '...'. Removing from resource list." for every adapter and port filter that does not contribute to the final filtered results. The formatting of the lsluns (8) man page is flawed. lsluns is used in unexpected or even unsupported ways. Problem: Scanning can be resource consumptive. So if a user already wants to filter, possibly to reduce resource consumption, he does not want to happen to scan everything and thus consume the worst case of resources. The message "No valid combination found for {adapter|port} '...'. Removing from resource list." is potentially confusing. It is unclear which combination is being referred to, especially if only one single adapter or port filter was specified. There is also no differentiation whether the denoted adapter or port exists for its own or not. It just does not exist in the final filtered results. The formatting of the lsluns (8) man page is flawed. The lsluns usage text and lsluns (8) man page lack the information on the intended use cases, requirements, and restrictions. Solution: Print a message and exit when all filters match nothing. Do not print confusing messages when a filter matches nothing. Fix man page formatting. Enhance usage text and man page. Clarify discovery use case, relation to NPIV and to zfcp auto LUN scan. Point out IBM Storwize configuration requirements. Document restriction to zfcp-only systems. Reproduction: Use lsluns and specify adapter bus-ID and/or target port WWPN filter(s) that do not match anything. Either specify inexistent bus-IDs and/or WWPNs or invalid filter arguments. Upstream-ID: e748fff3479f8f4ae7e8262b4913f6d08ff78f66 Problem-ID: 161888 Upstream-Description: lsluns: enhance usage statement and man page The wording in the lsluns usage statement and man page was misleading in several aspects: * lsluns does not list all LUNs, just those discovered in the FC SAN * lsluns -a should only be used to display the LUN encryption status Fix filter option arguments. Clarify filter option usage. Refer to lszfcp and lsscsi. Reported-by: Steffen Maier <maier@linux.vnet.ibm.com> Signed-off-by: Jens Remus <jremus@linux.vnet.ibm.com> Reviewed-by: Steffen Maier <maier@linux.vnet.ibm.com> Signed-off-by: Michael Holzheu <holzheu@linux.vnet.ibm.com> Signed-off-by: Jens Remus <jremus@linux.vnet.ibm.com> --- zconf/lsluns | 45 +++++++++++++++------------ zconf/lsluns.8 | 93 +++++++++++++++++++++++++++++++++++++++------------------ 2 files changed, 91 insertions(+), 47 deletions(-) --- a/zconf/lsluns +++ b/zconf/lsluns @@ -1,6 +1,6 @@ #!/usr/bin/perl # -# lsluns - Tool to list all available LUNs +# lsluns - list LUNs discovered in the FC SAN, or show encryption state of attached LUNs # # Copyright IBM Corp. 2008, 2017 # @@ -169,32 +169,39 @@ sub get_lun_hash sub lsluns_usage { print <<EOD; -Usage: $PROGRAM_NAME [<options>] +Usage: +$PROGRAM_NAME [-c <busid>] ... [-p <wwpn>] ... [-h] [-v] - lsluns provides information for LUNs. + List LUNs discovered in the Fibre Channel (FC) Storage Area Network (SAN). + This causes extra SAN traffic for each target port WWPN. - The default is to list all LUNs that are available via the attached ports. - The display can be limited by specifying an adapter or a port. +$PROGRAM_NAME -a [-c <busid>] ... [-p <wwpn>] ... [-h] [-v] + + Show encryption state of the attached LUNs. + This causes extra SAN traffic for each attached LUN. + +For all other uses, such as listing attached LUNs or properties other than +encryption, use other tools such as "lszfcp -D" or "lsscsi -tv". + +Limit the listing by specifying one or more adapters (FCP device +bus-IDs) or target port WWPNs or both. Options: - -a, --active - Shows all activated LUNs. - In addition LUN encryption information is provided. - e.g. "lsluns -a" - - -c, --ccw - Shows LUNs for a specific ccw device. - e.g. "lsluns -c 0.0.3922" - - -p, --port - Shows LUNs for a specific port. - e.g. "lsluns -p 0x5005123456789000" + -c <busid>, --ccw <busid> + Filter LUNs by adapter with the specified FCP device bus-ID. Can be + specified multiple times. + For example: "$PROGRAM_NAME -c 0.0.3922" + + -p <wwpn>, --port <wwpn> + Filter LUNs by target port with the specified WWPN. Can be specified + multiple times. + For example: "$PROGRAM_NAME -p 0x5005123456789000" -h, --help - Print help message and exit. + Print help message and exit. -v, --version - Display version info and exit. + Display version information and exit. EOD exit 0; } --- a/zconf/lsluns.8 +++ b/zconf/lsluns.8 @@ -2,61 +2,93 @@ .\" s390-tools is free software; you can redistribute it and/or modify .\" it under the terms of the MIT license. See LICENSE for details. .\" -.TH LSLUNS 8 "June 2008" "s390-tools" +.TH LSLUNS 8 "2017-02-17" "s390-tools" .SH NAME -lsluns \- list available LUNs +lsluns \- list LUNs discovered in the FC SAN, or show encryption state of +attached LUNs .SH SYNOPSIS .B lsluns +.RB [\| \-c +.IR busid \|]\ .\|.\|. +.RB [\| \-p +.IR wwpn \|]\ .\|.\|. +.\" --active +.br +.B lsluns \-a +.RB [\| \-c +.IR busid \|]\ .\|.\|. +.RB [\| \-p +.IR wwpn \|]\ .\|.\|. +.\" --help and --version +.br +.B lsluns .RB [\| \-h \|] .RB [\| \-v \|] -.RB [\| \-c -.IR adapter\ id:0.0.XXXX \|]\ .\|.\|. -.RB [ \-p -.IR port\ number:0xXXXXXXXXXXXXXXXX \|]\ .\|.\|. .SH DESCRIPTION .PP .B lsluns -does a listing of all available LUNs. - -The default is to list all LUNs that are found. The listing can be -limited by specifying an adapter or a port. +lists all logical unit numbers (LUNs) discovered in the +Fibre Channel (FC) Storage Area Network (SAN). +This causes extra SAN traffic for each target port WWPN. + +.B lsluns -a +shows the encryption state of the attached LUNs. +This causes extra SAN traffic for each attached LUN. + +Limit the listing by specifying one or more adapters (FCP device +bus-IDs) or target port WWPNs or both. + +For all other uses, such as listing attached LUNs or properties other than +encryption, use other tools such as +.B lszfcp \-D +or +.BR "lsscsi \-tv" . .SH OPTIONS .TP +.BR \-a ", " \-\-active +Show the encryption state of the attached LUNs. Encrypted devices are indicated +with a bracketed X immediately following the LUN number. +.TP +.BI \-c\ busid \fR,\ \fB\-\-ccw= busid +Filter LUNs by adapter with the specified FCP device bus-ID. This option can be +specified multiple times. When used in conjunction with \fB\-p\fR, only those +LUNs are listed that also satisfy at least one of the \fB\-p\fR constraints. +.TP +.BI \-p\ wwpn \fR,\ \fB\-\-port= wwpn +Filter LUNs by target port with the specified WWPN. This option can be +specified multiple times. When used in conjunction with \fB\-c\fR, only those +LUNs are listed that also satisfy at least one of the \fB\-c\fR constraints. +.TP .BR \-h ", " \-\-help Print help message and exit. .TP .BR \-v ", " \-\-version -Display version info and exit. -.TP -.BI \-c\ adapter \fR,\ \fB\-\-ccw= adapter -Shows LUNs for a specific adapter. -.TP -.BI \-p\ port \fR,\ \fB\-\-port= port -Shows LUNs for a specific port. -.TP -.BR \-a ", " \-\-active -Shows all activated LUNs. In addition information is provided -whether the LUN is encrypted or not. This is indicated with a bracketed X -right after the LUN number. +Display version information and exit. .SH EXAMPLES .TP .B "lsluns" .RS -Shows all available LUNs. +Lists all LUNs discovered in the FC SAN. .RE .TP .BI "lsluns \-c " 0.0.3922 -Shows all LUNs found on adapter \fI0.0.3922\fR. +Lists all LUNs discovered in the FC SAN on adapter \fI0.0.3922\fR. .TP .BI "lsluns \-p " 0x5005123456789000 -Shows all LUNs for port \fI0x5005123456789000\fR. +Lists all LUNs discovered in the FC SAN on target port +\fI0x5005123456789000\fR. .TP -.BI "lsluns \-c " 0.0.3922 " \-p " 0x5005123456789000 -Shows all LUNs for adapter \fI0.0.3922\fR and port \fI0x5005123456789000\fR. +.BI "lsluns \-c " 0.0.3922 " \-c " 0.0.fc00 \ +" \-p " 0x5005123456789000 " \-p " 0x5005abcdefabc000 +Lists all LUNs discovered in the FC SAN on: +adpater \fI0.0.3922\fR and port \fI0x5005123456789000\fR, +adapter \fI0.0.3922\fR and port \fI0x5005abcdefabc000\fR, +adapter \fI0.0.fc00\fR and port \fI0x5005123456789000\fR, or +adapter \fI0.0.fc00\fR and port \fI0x5005abcdefabc000\fR. .TP .B "lsluns -a" adapter = 0.0.3c02 @@ -64,4 +96,9 @@ adapter = 0.0.3c02 lun = 0x401040a200000000(X) /dev/sg0 Disk IBM:2107900 lun = 0x401040a300000000 /dev/sg1 Disk IBM:2107900 -Shows all active LUNs including the information whether the device is encrypted or not. +Shows the encryption status of attached LUNs. A bracketed X suffixed to a LUN +indicates that the device is encrypted. + +.SH "SEE ALSO" +.BR lszfcp (8), +.BR lsscsi (8)
Locations
Projects
Search
Status Monitor
Help
OpenBuildService.org
Documentation
API Documentation
Code of Conduct
Contact
Support
@OBShq
Terms
openSUSE Build Service is sponsored by
The Open Build Service is an
openSUSE project
.
Sign Up
Log In
Places
Places
All Projects
Status Monitor